With an innovative modular design, we offer physically separated private suites (DC in a DC) to meet high on compliance and high volume colocation requirements from enterprises. These private suites are designed keeping in mind varied quantum of racks with various power capacities, critical operations and security needs.
State-Of-The-Art equipped Plug-And-Play ready space available for customer as per their requirement for deploying their own cabinets and IT equipment.
Designed for enterprises looking for flexible options but desiring to retain complete control over their environment, from environmental conditions to security.
We provide secure lockable rack cabinets with power and high speed network connectivity in modular data suites of varied sizes to co-locate compute, storage and network appliances. These data suites are equipped with dedicated air conditioning. These digitally secured cabinets are available as a part of dedicated suite and shared suite depending on customer requirements.
This is suitable for enterprises who want to leverage a shared rack to co-locate handful of IT appliances on a "Per U" basis, yet enjoying a fully redundant data center environment. This is backed by independent N+N power and cable feeds. Best suited for starting small and scaling at will.
Our Hands and Feet Support helps in assisting customers in preliminary physical checks of their hosted environment, port & cabling checks, reporting equipment indicators and on-demand physical re-boots. This service plays a crucial role of an extended arm for customers who do not have personnel presence inside the data center.
It is imperative to get the right advice when building your data center; right from the conceptualization phase. From selecting land/location to sizing the data center's capacity that suits your current and prospective prerequisites. Our proficient team can comprehend your requirements and prepare a thorough assessment and its associated estimated cost. Sizing the data center is a critical factor in controlling your expenses. Understanding the requirements and appropriate advice on sizing for power, cooling, and other electrical & mechanical components is a must. Further detailing includes estimating the Construction Area, Compartmentalization, and Load-bearing Capacity, among others.
Seismic Zone Category
History of Natural Calamities
Fiber Connectivity
Power
Water Supply
Ease of Regulatory Approvals
Pi Data Centers have extensive operating experience, with large to medium size data centers, for enterprises and governments. Our data center operation comprises systems and workflows within a data center that keeps it running. It includes installing and maintaining network resources, ensuring data center security, and monitoring systems for power and cooling. The IT requirements of companies that own data centers define many types of data centers, varying in size, reliability, and redundancy. The growth of cloud computing is pushing data centers to modernize, including updated operations that take advantage of virtualization and automation. As time-tested and industry weighted data center operators, we bring in the expertise & in-depth knowledge to put all the dots together and bridge the gaps as your trusted partner to operate your data center.
The Data Center design is the vital aspect that determines your total CAPEX and the OPEX. Once the implementation completes, it becomes problematic to undo a sub-optimal design. However, an optimal design can save Millions regarding CAPEX and OPEX. The Pi design team consists of UPTIME-Certified Architects(ATDs) who can bring your vision to reality through their experience and expertise by assimilating essential features required for a Data Center to run. The design includes the Master plan, Structural design, Mechanical & Electrical Design Drawings, HVAC, Security/ Surveillance, Fire Suppression, Access Controls, and End-to-End Automation. Our deliverables also include Design Certifications.
Know MoreData Center build differs from traditional buildings, and the load-bearing, compartmentalization, and significant structural spans play a critical role. However, often it is easy to overdo the sizing, which inflates the overall cost unless it is designed and built appropriately. We have expertise in selecting the right construction partner for the civil and M&E phases of the project, among others, to execute the build of the DC in the stipulated time. Getting construction & statutory approvals on time is imperative. Our experts have outstanding experience with feet on the ground working with the relevant statutory bodies that will help you achieve the best.
Know MoreTo ensure on-time completion, addressing the project timelines is critical besides the quality task and process being implemented. The PMC encloses execution and completion of the scope of all the essential aspects, including Civil, Electrical, and Mechanical, which contains low side, HVAC, Security/ Surveillance, Fire Suppression, Access Controls, and end-to-end automation. Once the project is completed, we ensure end-to-end testing with the appointed agency to ensure validation against the design parameters before handing it over.
Know MoreWith an innovative modular design, we offer physically separated private suites (DC in a DC) to meet high on compliance and high volume colocation requirements from enterprises. These private suites are designed keeping in mind varied quantum of racks with various power capacities, critical operations and security needs.
State-Of-The-Art equipped Plug-And-Play ready space available for customer as per their requirement for deploying their own cabinets and IT equipment.
Designed for enterprises looking for flexible options but desiring to retain complete control over their environment, from environmental conditions to security.
We provide secure lockable rack cabinets with power and high speed network connectivity in modular data suites of varied sizes to co-locate compute, storage and network appliances. These data suites are equipped with dedicated air conditioning. These digitally secured cabinets are available as a part of dedicated suite and shared suite depending on customer requirements.
This is suitable for enterprises who want to leverage a shared rack to co-locate handful of IT appliances on a "Per U" basis, yet enjoying a fully redundant data center environment. This is backed by independent N+N power and cable feeds. Best suited for starting small and scaling at will.
Our Hands and Feet Support helps in assisting customers in preliminary physical checks of their hosted environment, port & cabling checks, reporting equipment indicators and on-demand physical re-boots. This service plays a crucial role of an extended arm for customers who do not have personnel presence inside the data center.
Uptime Institute Tier IV Certified
Built on 10 acre datacenter campus (1st and only in India)
No of Racks Upto 5000
Built Up Area 50,00,00 Sq.ft
Power Capacity Upto 60 MW (dedicated in campus substation)
Security Levels Eight Levels Of Stringent Security Layers
1. 2N Fault-Tolerant modular architecture providing at least 48 hours power outage protection.
2. Utility power through independent routes from dual substations
3. Lowest power cost in the Industry
Read moreUptime Institute Tier III Design Compliant (Build To Suit)
No. of Racks 83
White Tile Area 2,100 sq. Ft.
Expandable Rack Capacity 200 (Additional)
Expandable White Tile Area 5000 sq. Ft. (Additional Capacity)
Power Capacity 3 MW
Security Levels Four Levels of Stringent Security Layers
Rated Power Density per Rack 6 - 10 KVA
1. N+1 Fault-Tolerant Modular Architecture provides at least 48 hours of Power Outage Protection.
2. Utility Power through Independent Routes from Dual Substations
3. 2N Uninterruptible UPS, DG set and Redundant Utility Power
4. N+1 cooling system redundancy for better temperature management
5. Global standard uptime of 99.982%
Read moreUptime Institute Tier 3 Design Compliant
No of Racks 200
Built-Up Area 20,000 Sq.ft
Power Capacity 3MW
Security Levels Eight Levels Of Stringent Security Layers
1.N+1 Fault-Tolerant modular architecture provides at least 48 hours of power outage protection.
2.Utility power through independent routes from dual substations
Read moreRoom Temperature 22+/-2 deg. C
Relative Humidity 50+/-10%
(controlled by de-humidifiers)
Room Temperature 22+/-2 deg. C
Relative Humidity 50+/-10%
Room Temperature 22+/-2 deg. C
Relative Humidity 50+/-10%
Supply Temperature 8 deg. C
Return Temperature 10 deg. C
Room Temperature 22+/-2 deg. C
Relative Humidity Less than 70 deg. C
Modular Private Data Suites with capacities of 60 Racks and 120 Racks each, with total facility capacity of up to 5000 Racks. Each suite is dedicated or a multi-tenant environment in itself.
Pi Vijayawada is a 100% automated SCADA/DCIM facility wherein all electrical, mechanical, HVAC, fire safety, security and surveillance equipment are monitored live and can be controlled instantly with a click of a button from the Global Command Center located within the facility.
8 levels of stringent security from the main entrance to the data racks. All Data suites and NOCs are provided with biometric/physical key access and are monitored and managed by the iBMS.
Exclusive Customer-NOCs for Enterprises to manage their network, systems, applications and security in a private secured environment.
Plug-And-Play private suites enable customers to quickly colocate their IT infrastructure at Pi, rather than taking months at traditional data centers.
Innovative data center design, better PUE, low Power cost and Flexible business model translate to significant cost savings for our customers.
Modular Private Data Suites with capacities of 60 Racks and 120 Racks each, with a total facility capacity of up to 5000 Racks. Each suite is dedicated to a multi-tenant environment in itself.
Pi Vijayawada is a 100% automated SCADA/DCIM facility wherein all electrical, mechanical, HVAC, fire safety, security and surveillance equipment are monitored live and can be controlled instantly with a click of a button from the Global Command Center located within the facility.
8 levels of stringent security from the main entrance to the data racks. All Data suites and NOCs are provided with biometric/physical key access and are monitored and managed by the IBMS.
Exclusive Customer-NOCs for Enterprises to manage their network, systems, applications and security in a private secured environment.
Plug-And-Play private suites enable customers to quickly colocate their IT infrastructure at Pi, rather than taking months at traditional data centers.
Innovative data center design, better PUE, low Power cost and Flexible business model translate to significant cost savings for our customers.